Quality Low Voltage Surge Protection Device Spd DIN Rail Mount Surge Suppression Device 220V 10kA 25kA factory
<
Quality Low Voltage Surge Protection Device Spd DIN Rail Mount Surge Suppression Device 220V 10kA 25kA factory
Quality Low Voltage Surge Protection Device Spd DIN Rail Mount Surge Suppression Device 220V 10kA 25kA factory
Quality Low Voltage Surge Protection Device Spd DIN Rail Mount Surge Suppression Device 220V 10kA 25kA factory
Quality Low Voltage Surge Protection Device Spd DIN Rail Mount Surge Suppression Device 220V 10kA 25kA factory
>

Low Voltage Surge Protection Device Spd DIN Rail Mount Surge Suppression Device 220V 10kA 25kA

Product Summary

SLV-10S/SLV-20S is a compact ultra-low residual voltage surge protection device designed for single-phase power supply systems, ideal for fine lightning protection in LPZ 1-2 and subsequent lightning protection zones. As a series-installed fine arrester at the front end of equipment, it integrates ...

Product Custom Attributes

Model:
SLV-10S / SLV-20S
SPD Type:
T2、T3 (IEC 61643.11)
Nominal Operating Voltage (Un):
220Vac(50Hz)
Maximum Continuous Operating Voltage (Uc):
320Vac(50Hz)
Nominal Discharge Current (In):
10kA (SLV-10S) / 20kA (SLV-20S)
Maximum Discharge Current (Imax):
25kA (SLV-10S) / 40kA (SLV-20S)
Voltage Protection Level (Up):
≤0.8kV (SLV-10S) / ≤1.0kV (SLV-20S)
Response Time:
≤25ns
Highlight:

220V Low Voltage Surge Protection Device

,

25kA Surge Protection Device Spd

,

DIN Rail Mount Surge Suppression Device

Basic Properties

Place of Origin:
Guangdong Province.China
Brand Name:
LLH
Model Number:
SLV-10S
Document:

Trading Properties

Minimum Order Quantity:
1 piece
Price:
USD$42-USD$45
Packaging Details:
bos
Delivery Time:
7-15 days
Payment Terms:
L/C,D/A,D/P,T/T,Western Union
Supply Ability:
5000-10000 pieces/mouth

Product Description

SLV-10S/SLV-20S is a compact ultra-low residual voltage surge protection device designed for single-phase power supply systems, ideal for fine lightning protection in LPZ 1-2 and subsequent lightning protection zones. As a series-installed fine arrester at the front end of equipment, it integrates full-mode protection to shield against surges in line-neutral, line-earth, and neutral-earth paths.

Equipped with LED status indication (green: normal; red: failed) and open-circuit failure mode, it provides clear operational status and safe fault handling. The compact size (97mmx69mmx55mm) and 35mm DIN Rail mounting make it suitable for space-constrained environments. It supports parallel connection for loads exceeding 15A without changing residual voltage, making it versatile for homes, offices, and light industrial equipment protection.
 

Applications
● Single-phase power systems in residential buildings, offices, and small commercial spaces
● Front-end protection for household appliances, office equipment, and sensitive electronics
● Light industrial single-phase equipment and control systems
● Indoor power supply lines in apartments, shops, and small workshops
● Auxiliary equipment protection in communication rooms and data centers

 

Product features


Low Voltage Surge Protection Device Spd DIN Rail Mount Surge Suppression Device 220V 10kA 25kA 0

Standards
IEC 61643.11
SPD typeT2,T3
ModelsSLV-10SSLV-20S
Nominal operating voltage Un220Vac(50Hz)
Maximum continuous operating voltage Uc320Vac(50Hz)
Nominal discharge current (8/20μs)In10kA20kA
Maximum discharge current (8/20μs) Imax25kA40kA
Voltage protection level In@Up≤0.8kV≤1.0kV
L-N,L-E,N-E(3kA&6kV) Uoc≤650V
Response time tA≤25ns
Load current IR
15A
(Load greater than 15A can be connected in parallel, and the residual voltage remains unchanged)
Failure modeopen circuit
Deterioration indicationLED green: OK; LED red: Fail
Protection CircuitL-N,L-E,N-E

 

Mechanical parameters

 

Installation method
DIN Rail 35mm
Screw torque3N*m
Strip length10mm
Wiring cross-sectional area2.5mm²-10mm²
Product size97mmx69mmx55mm
Shell material and surface technologyShell material and surface technology
Installation positionIndoor
Degrees of protection provided by enclosureIP20
Temperature range-40℃…+80℃
Humidity rangeRelative humidity ≤ 95% (max 40 ℃)

 

Notices

1.For loads exceeding 15A, parallel installation of multiple SPDs is allowed to maintain protection performance.

2.Use wiring with cross-sectional area 2.5mm²-10mm² and tighten screws to 3N·m torque.

3.Ensure reliable grounding with ground resistance ≤4Ω to guarantee surge diversion efficiency.

4.Replace the SPD immediately if the LED indicator turns red (failure status) or after severe surge impact.

5.Do not disassemble the product; improper operation may damage internal components.

6.Avoid using in environments beyond the specified temperature and humidity range.

 

FAQ

Q1: Can SLV-10S/SLV-20S be used for air conditioners or refrigerators?

A1: Yes, it is suitable for protecting household appliances with rated current ≤15A; for larger loads, parallel installation is recommended.

 

Q2: What is the difference between SLV-10S and SLV-20S?

A2: The core difference is discharge current: SLV-10S has In=10kA/Imax=25kA, while SLV-20S has In=20kA/Imax=40kA. Other parameters and design are consistent.

 

Q3: Does the product support hot-swapping?

A3: No, hot-swapping is not supported. Please disconnect the power supply before replacing the SPD.

 

Q4: What is the failure mode of this SPD?

A4: It adopts open-circuit failure mode, which automatically disconnects from the circuit when faulty to avoid short circuits or other hazards.

 

Q5: Can it be installed outdoors?

A5: No, it is designed for indoor use only. For outdoor applications, choose products with IP67 protection level.
 