Wind Power Renewable Energy T2 SPD 690V 40kA 80kA Industrial High Voltage Protection
Product Summary
LPM 40-760/4/LPM 50-760/4 is a T2 level power surge protector specifically designed for wind power generation systems. It is engineered to withstand the high-voltage requirements of wind power systems (690Vac nominal voltage), providing reliable protection against transient overvoltages caused by ...
Product Custom Attributes
T2 SPD 690V
,Industrial T2 SPD
,T2 Surge Protector 40kA
Basic Properties
Trading Properties
Product Description
LPM 40-760/4/LPM 50-760/4 is a T2 level power surge protector specifically designed for wind power generation systems. It is engineered to withstand the high-voltage requirements of wind power systems (690Vac nominal voltage), providing reliable protection against transient overvoltages caused by lightning strikes and power grid fluctuations.
|
Product Features
|
|
● Independent integrated module for each pole
|
|
● Built-in ultra-low temperature release mechanism
|
|
● Equipped with indication windows and remote signaling contacts
|
Application scenarios

Product Specification

| Standards | IEC 61643-11 |
| SPD type | T2 |
| Models |
LPM 40-760/4 LPM 50-760/4 |
| Nominal operating voltage Un | 690Vac(50Hz) |
| Maximum continuous operating voltage Uc | 760Vac(50Hz) |
| Nominal discharge current (8/20μs)In | 40kA/50kA |
| Maximum discharge current (8/20μs) Imax | 80kA/100kA |
| Voltage protection level In@Up | ≤3.0kV/≤3.2kV |
| Response time tA | ≤25ns |
| Protection Circuit | L1,L2,L3,N-E |
Mechanical parameters
| Installation method | DIN Rail 35mm |
| Screw torque | 5N*m |
| Strip length |
12mm
|
| Wiring cross-sectional area | 2.5mm²-32mm² |
| Product size | 90mmx144mmx68mm |
| Shell material and flame retardant grade | Mineral nylon PA6, V0 |
| Deterioration indication | Window red: Fail |
| Remote signaling contact type | Normally closed and normally open switching contacts |
| Remote signaling contact switching ability | 125Vac/1A,125Vdc/0.2A |
| Maximum connection capacity of remote signaling | 2.5mm² |
| Installation position | Indoor |
| Degrees of protection provided by enclosure | IP20 |
| Temperature range | -40℃…+80℃ |
| Humidity range | Relative humidity ≤ 95% (max 40 ℃) |
Notices
● Confirm the wind power system voltage matches 690Vac(50Hz) before installation.
● Use wiring with cross-sectional area 2.5mm²-32mm² and tighten screws to 5N·m torque.
● Regularly check the indication window—replace the product immediately if it turns red (failure status).
● Ensure the grounding system meets wind power industry requirements (ground resistance ≤4Ω).
● The product is designed for indoor use in wind turbine control cabinets; avoid outdoor exposure.
● Select the appropriate model based on the required discharge current (40kA/50kA).
FAQ
Q1: What is the maximum continuous operating voltage of this product?
A1: The maximum continuous operating voltage (Uc) is 760Vac, suitable for 690Vac wind power systems.
Q2: Can it be used in solar power systems?
A2: No, this model is designed for high-voltage AC wind power systems. For solar PV systems, choose LPM PV series DC SPDs.
Q3: What is the function of the built-in ultra-low temperature release mechanism?
A3: It ensures the product operates safely in low-temperature environments (-40℃) and disconnects faulty modules to avoid hazards.
Contact Our Experts And Get A Free Consultation!