Quality Grounding Resistance Monitor MODBUS Resistance Tester Lightning Monitor with Alarm RS485 RS232 factory
<
Quality Grounding Resistance Monitor MODBUS Resistance Tester Lightning Monitor with Alarm RS485 RS232 factory
Quality Grounding Resistance Monitor MODBUS Resistance Tester Lightning Monitor with Alarm RS485 RS232 factory
Quality Grounding Resistance Monitor MODBUS Resistance Tester Lightning Monitor with Alarm RS485 RS232 factory
>

Grounding Resistance Monitor MODBUS Resistance Tester Lightning Monitor with Alarm RS485 RS232

Product Summary

Product description ● Flexible mounting & standard protocol: Supports 35mm DIN rail mounting and flat panel mounting, equipped with a 1-inch OLED display and compliant with MODBUS-RTU communication protocol. ● 1-group EPIC test terminal: Designed for connecting grounding electrodes, voltage test ...

Product Custom Attributes

Measurement Mode:
THREE-POLE: Grounding Resistance Test; Two-pole: Equipotential Connection Resistance
Method Of Measurement:
Rated Electrorheological Pole Method, Measuring Current 10-100mA, 10-800Hz Adjustable
Test Value:
Average/maximum/minimum, The Display Displays The Average
Measuring Time:
8/S Per Turn, Adjustable
Highlight:

RS485 Grounding Resistance Monitor

,

MODBUS Resistance Tester Lightning Monitor

,

Lightning Monitor with Alarm

Basic Properties

Place of Origin:
Guangdong Province.China
Brand Name:
LLH
Model Number:
LS-ER200
Document:

Trading Properties

Minimum Order Quantity:
1 piece
Price:
US $236/Piece
Packaging Details:
1 piece/box
Delivery Time:
7-15 days
Payment Terms:
L/C,D/A,D/P,T/T,Western Union
Supply Ability:
5000-10000 pieces/mouth

Product Description

Product description
Flexible mounting & standard protocol: Supports 35mm DIN rail mounting and flat panel mounting, equipped with a 1-inch OLED display and compliant with MODBUS-RTU communication protocol.
1-group EPIC test terminal: Designed for connecting grounding electrodes, voltage test electrodes, and current test electrodes respectively.
Multiple measurement principles: Adopts three-pole method, two-pole method, and voltage-current method for comprehensive testing.
Precise resistance measurement: Capable of measuring maximum/minimum/average grounding resistance, with a measurement range of 0~200Ω and 0.01Ω resolution.
Dual power supply options: Supports both DC 12V and AC 220V power input for flexible deployment.
Automatic isolation switch: Built-in isolation switch on the EPIC port, which automatically turns on during testing and off after completion.
Intuitive status indication: Features power supply, test, and communication indicators, plus a manual test button for on-demand operation.
Audible alarm function: Built-in buzzer that triggers an alarm when the measured resistance exceeds the preset threshold (alarm value configurable).

 

 

Technical parameters
 
Grounding Resistance Monitor MODBUS Resistance Tester Lightning Monitor with Alarm RS485 RS232 0
Models
LS-ER200
Power
220VAC, 12VDC optional
P.W
5W
Display screen
1 Inch OLED
Communication interface

RS485:

Baud rate Default 9600; check bit n; Data Bit 8; Stop Bit 1

Device Address 1 ~ 255 optional, Default 1
 
RS232:
Dedicated communication interface for accessing lightning current peak monitoring instrument
Measurement mode
THREE-POLE: Grounding Resistance Test; two-pole: Equipotential Connection Resistance
Method of measurement
Rated electrorheological pole method, measuring current 10-100mA, 10-800Hz adjustable
Test value
Average/maximum/minimum, the display displays the average
Measuring time
8/S per turn, adjustable
Overflow display
The test value over the range of the quantum is displayed on OL
Test Range
0~200Ω
Resolution
0.01Ω
Overload protection
AC280V, 3 seconds between the Poles
Shell material
Black aluminum alloy red plastic stand
Installation mode
Support Standard 35 mm track mount and122mm*88mmMounting Hole
Working Environment
-40~85℃,0~95% RH

 

 

FAQ

1.Q: Can the LS-ER200 be customized (e.g., power supply or communication interface)?
A: Yes, we support full customization. You can choose between 220VAC or 12VDC power supply, and adjust RS485 parameters (baud rate, address) or alarm thresholds to match your system.

 

2.Q: What is the MOQ? Can we place a small trial order?
A: We accept small trial orders with a standard MOQ of 1 unit, supporting both sample and bulk purchases.

 

3.Q: How long is the lead time? Can we get priority production for urgent projects?
A: Standard lead time is 7-15 working days. We can arrange priority production for urgent orders to meet your project schedule.

 

4.Q: What is the warranty period? How do you handle after-sales issues?
A: We offer a 2-3 year warranty. Non-human-caused failures within the warranty period can be replaced or repaired free of charge.

 

5.Q: Can we get test samples? How are sample fees and shipping costs calculated?
A: Test samples are available. Sample fees are required in advance and can be deducted from bulk order payments. Shipping costs are usually collected separately or negotiated.

 

Attachments

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.