전압 보호 장치 PLC 및 산업 제어판을 위한 3단계 SPD
Product Description 4-pole Type 2 SPD engineered for three-phase industrial automation cabinets, installed in LPZ0B-LPZ1 secondary lightning zones to protect PLCs, inverters and servo systems from lightning surges and grid switching transient overvoltage. Full L1/L2/L3-N-E circuit diverts surge currents with ≤ 25ns fast response to clamp dangerous high voltage. Operating temperature range -40 ℃ to +70 ℃ fits cold workshops and hot equipment rooms, anti-vibration modular
전압 보호 장치. 전기 충전소 보조 전원 캐비닛용 3단계 SPD
Product Description Three-phase auxiliary distribution cabinets inside EV charging stations are vulnerable to lightning induced surges and grid switching impulses, which cause charger mainboard and metering module breakdowns and downtime. This 4-pole Type 2 SPD is mounted in LPZ0B-LPZ1 secondary panels within charging stations, diverting lightning transient currents with 40kA surge capacity and clamping residual voltage within safe limits via ≤ 25ns fast response to protect
RS485 RS232 낙뢰 감지기 접지 저항 감지기 220V AC 12V DC
Product description ● Support for standard 35mm rail mounting and flat panel mounting, 1 inch OLED display, Standard MODBUS-RTU protocol. ● 1 group E/P/C test terminal for connecting grounding electrode, voltage test electrode and current test electrode respectively. ● Two-pole method, three-pole method, volt-ampere method test principle. ● Maximum/minimum/average grounding resistance can be measured. Resistance Test Range 0 ~ 200 Ω,resolution 0.01 Ω ● Can Choose 1 DC 12V
접지 저항 모니터 MODBUS 저항 테스터 낙뢰 모니터 알람 RS485 RS232 포함
Product description ● Flexible mounting & standard protocol: Supports 35mm DIN rail mounting and flat panel mounting, equipped with a 1-inch OLED display and compliant with MODBUS-RTU communication protocol. ● 1-group EPIC test terminal: Designed for connecting grounding electrodes, voltage test electrodes, and current test electrodes respectively. ● Multiple measurement principles: Adopts three-pole method, two-pole method, and voltage-current method for comprehensive
전압 보호 장치 40kA 최대 방출 2형 3단계 SPD
Product Description This 4-pole Type 2 surge protection device is engineered for 320Vac three-phase distribution systems, mounted in LPZ0B-LPZ1 distribution cabinets. With 40kA maximum discharge capacity, it diverts heavy lightning surges and limits voltage protection level ≤ 1.5kV to prevent transient overvoltage damage on industrial controllers and building power meters. Anti-vibration modular structure fits constantly vibrating factory cabinets, with built-in thermal
전압 보호 장치. 상업용 건물 전력 패널용 3단계 전압 차단기.
Product Description 4-pole Type 2 SPD fits three-phase power distribution systems in commercial buildings, mounted on floor secondary panels within LPZ0B-LPZ1 zones to shield lighting, air conditioning, CCTV and office electronics from induced lightning surges and grid voltage fluctuations. Multiple Uc ratings (275/320/385/440Vac) match global commercial mains standards. Pluggable modules simplify property maintenance replacement, V0 flame retardant housing mitigates cabinet
서지 보호 장치 | 높은 연속 전압 440Vac 삼상 서지 피뢰기
Product Description Type 2 surge protective device exclusively designed for 440Vac high-voltage three-phase distribution systems, installed in heavy-duty industrial control cabinets and large commercial secondary panels within LPZ0B-LPZ1 zones. It diverts lightning and grid switching surges with voltage protection level ≤ 2.0kV to safeguard large inverters and power control cabinets. 4-pole full L1/L2/L3/N-E circuit protection with 40kA maximum discharge capacity handles
전압보호장치 3단계 SPD 실험실 정밀 측정기
Product Description Laboratory precision measuring instruments are highly sensitive to voltage fluctuations and lightning surges; transient high voltage causes sensor calibration drift and permanent circuit damage. This 4-pole Type 2 SPD is installed on lab three-phase incoming distribution panels. The low voltage variant delivers residual voltage as low as ≤ 1.25kV with ≤ 25ns nanosecond-level response to divert surge currents and contain impulse voltage within instrument
전압보호장치
Product Description Integrated non-detachable SPDs require full removal and complete rewiring upon failure, increasing maintenance time and loose wiring risks. This SPD adopts split base + independent pluggable module structure: when one module degrades, only the faulty unit needs extraction and replacement with all base, phase and PE wiring untouched to cut on-site wiring labor. Anti-loose locking buckles resist long-term cabinet vibration, while each single module