Quality Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD factory
<
Quality Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD factory
Quality Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD factory
Quality Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD factory
>

Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD

Product Summary

LPX-40C is a three-phase AC power lightning protection box, specifically designed for three-phase power supply systems to provide comprehensive surge protection against transient overvoltages caused by lightning strikes and power grid fluctuations. Benefits Industrial-Grade Stability: Features ...

Product Custom Attributes

Standards:
IEC 61643.11
SPD Type:
T2
Maximum Continuous Operating Voltage (Uc):
385Vac(50Hz)
Maximum Discharge Current (Imax):
40kA/ 80kA
Response Time:
≤25ns
Highlight:

AC Whole House Surge Protectors

,

Whole House Surge Protectors 220V

,

Lightning Protection T2 SPD

Basic Properties

Place of Origin:
Guangdong Province.China
Brand Name:
LLH
Model Number:
LPX-40C
Document:

Trading Properties

Minimum Order Quantity:
1 piece
Price:
US $79/Piece
Packaging Details:
box
Delivery Time:
7-15 days
Payment Terms:
L/C,D/A,D/P,T/T,Western Union
Supply Ability:
5000-10000 pieces/mouth

Product Description

LPX-40C is a three-phase AC power lightning protection box, specifically designed for three-phase power supply systems to provide comprehensive surge protection against transient overvoltages caused by lightning strikes and power grid fluctuations.

Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD 0
 
Benefits
Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD 1Industrial-Grade Stability: Features optional mode protection and a reliable PCB design for stable, interference-resistant performance in harsh industrial environments.
Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD 2Precise Surge Counting: Built-in lightning stroke counter (0.5kA–80kA, 0–999 digits) records surge occurrences for predictive maintenance.
Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD 3Remote Monitoring: Remote signaling and status indication enable real-time operational monitoring and centralized management.
 

Applications

Suitable for installation in LPZ 1-2 and subsequent lightning protection zones, suitable for fine lightning protection devices in three-phase power supply systems.

Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD 4   Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD 5   Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD 6    Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD 7

 

Product Specification

 

Lightning Protection 3 Phase AC Whole House Surge Protectors 220V 20kA 40kA T2 SPD 8

 

Standards IEC 61643.11
SPD type T2
Models LPX-40C, LPX-80C
Nominal operating voltage Un 220Vac(50Hz)
Maximum continuous operating voltage Uc 385Vac(50Hz)
Nominal discharge current (8/20μs) In 20kA, 40kA
Maximum discharge current (8/20μs) Imax 40kA, 80kA
Voltage protection level Up ≤1.25kV, ≤1.8kV
Response time tA ≤25ns
Protection Circuit L1,L2,L3-N,N-E
Lightning stroke range 0.9kA(8/20μs)~80kA(8/20μs)
Counting digit 0~999

 

Mechanical Parameters

 

Installation method 4 fixed holes, DIN Rail 35mm
Screw torque 5N·m
Strip length 12mm
Wiring cross-sectional area 2.5mm²~10mm²
Product size 178mm×116mm×75mm, 197mm×139mm×90mm
Shell material and surface technology Cold rolled steel plate painted black
Alarm system - Deterioration indication LED green: OK; Off: Fail
Remote signaling contact type Normally closed and normally open switching contacts
Remote signaling contact switching ability 125Vac / 1A, 125Vdc / 0.2A
Maximum connection capacity of remote signaling 2.5mm²
 
Installation Tips

1.Install the lightning protection box in a dry, well-ventilated indoor environment, and keep it away from flammable materials.

2.Use wires with a cross-sectional area of 2.5mm²~10mm², and tighten the screws to a torque of 5N·m.

3.Ensure reliable earthing, with a ground resistance ≤4Ω, to achieve optimal surge discharge effect.

4.Regularly check the lightning count and status indicator: if the product fails, the indicator will turn off. Replace the faulty device in a timely manner.

5.Do not connect the product to a power supply that exceeds its rated voltage and current.

6.Avoid using the product beyond the specified temperature and humidity ranges.


FAQ
Q1: What is the counting range of the lightning strike counter?
A1: The counter can record lightning strikes with a discharge current ranging from 3kA(8/20μs) to 80kA(8/20μs), with a digital display range of 0 to 999.
 
Q2: Does the product support remote monitoring?
A2: Yes. It is equipped with normally closed and normally open remote signaling contacts, allowing connection to a monitoring system for remote status tracking.
 
Q3: What is the difference between LPX-40C and LPX-80C?
A3: The core difference lies in the maximum discharge current (Imax): LPX-40C has an Imax of 40kA, while LPX-80C has an Imax of 80kA, making them suitable for different system protection requirements.
 
Q4: Can it be installed in outdoor environments?
A4: No. This product is designed for indoor use only. For outdoor applications, please select products with an IP67 protection level.

Attachments

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.