Outdoor Led Surge Protection Device 220V 320V 10kA 20kA IP67 T2 T3 SPD
Product Summary
The LPC Series is a dedicated surge protector engineered for LED street lights and high-power outdoor electrical equipment, ideal for installation in LPZ 2-3 and subsequent lightning protection zones. It features a two-port full-mode protection architecture, delivering all-round surge shielding for ...
Product Custom Attributes
Led Surge Protection Device 220V
,IP67 Led Surge Protection Device
,T2 Led Surge Protector
Basic Properties
Trading Properties
Product Description
The LPC Series is a dedicated surge protector engineered for LED street lights and high-power outdoor electrical equipment, ideal for installation in LPZ 2-3 and subsequent lightning protection zones. It features a two-port full-mode protection architecture, delivering all-round surge shielding for line-neutral, line-earth, and neutral-earth paths.
With its ultra-compact dimensions (42mm×30mm×23mm) and tool-free installation, it is perfectly suited for space-constrained outdoor scenarios. The IP67-rated enclosure ensures dustproof and waterproof performance, while the V0 flame-retardant nylon housing offers exceptional durability and corrosion resistance, making it reliable for both indoor and outdoor deployments.
| Product Features |
● Two ports, full mode protection |
●Small size and easy installation |
●Protection level up to IP67 |
●Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, installed in series at the front end of the final level equipment of the AC/DC power supply system, widely used as lightning protectors for LED street lights, sensors, and other equipment. |
Product Specification

Standards | IEC 61643-11 | |
SPD type | T2,T3 | |
Models | LPC 5-320 | LPC-10-320 |
Electrical parameters | ||
Nominal operating voltage Un | 220Vac(50Hz) | |
Maximum continuous operating voltage Uc | 320Vac(50Hz) | |
Nominal discharge current (8/20μs)In | 5kA | 10kA |
Maximum discharge current (8/20μs) Imax | 10kA | 20kA |
Voltage protection level In@Up | ≤1.25kV | ≤1.5kV |
Load current | 10A | 10A |
Response time tA | ≤25ns | ≤25ns |
Protection Circuit | L-N,L-E,N-E | L-N,L-E,N-E |
Failure and alarm | ||
Deterioration indication | LED green: OK; Off: Fail (optional function) | |
Fixed method | φ4mmFixing lug |
Wire length | 200mm |
Wire cross-sectional area | 1.5mm² |
Product size | 42mmx30mmx23mm |
Shell material and flame retardant grade | Nylon,VO |
Installation position | Indoor and outdoor |
Degrees of protection provided by enclosure | IP67 |
Temperature range | -40℃…+80℃ |
Humidity range | Relative humidity ≤ 95% (max 40 ℃) |
Notices
1.Installation Scenario: Designed for series installation at the front end of LED street lights and high-power outdoor equipment, within LPZ 2-3 or subsequent lightning protection zones.
2.Mounting Method: Use the included φ4mm fixing lugs for secure installation, ensuring resistance to wind and vibration in outdoor environments.
3.Wiring Requirements: Utilize the pre-attached 200mm wires (1.5mm² cross-sectional area) for convenient wiring; ensure proper sealing of wiring connections to maintain IP67 protection.
4.Load Limit: Do not exceed the maximum 10A load current to prevent overheating and ensure device longevity.
5.Status Monitoring: If the optional green LED indicator is off (indicating device failure) or after severe surge impact, replace the SPD immediately to maintain protection.
6.System Compatibility: This product is designed for AC 220Vac(50Hz) systems; confirm the system voltage matches before installation.
FAQ
Q1: What is the maximum load current this LPC Series SPD can handle?
A1: It supports a maximum load current of 10A, making it suitable for high-power LED street lights and other outdoor equipment with moderate power demands.
Q2: What are the key differences between the LPC Series and LPF Series SPDs?
A2: The LPC Series features a two-port design and 10A load current capacity, tailored for high-power outdoor equipment. In contrast, the LPF Series uses a one-port design without a specified load current limit, intended for general-purpose equipment applications.
Q3: Is this product suitable for coastal areas with high humidity?
A3: Yes. Its IP67 ingress protection and corrosion-resistant nylon housing make it highly suitable for high-humidity and corrosive coastal environments.
Q4: Can this SPD be used for other outdoor equipment besides LED street lights?
A4: Absolutely. It is compatible with a wide range of high-power outdoor electronic devices, including large-scale sensors, outdoor monitoring equipment, and other industrial outdoor units.
Q5: What are the specifications of the pre-attached wires?
A5: The product comes with 200mm-long wires with a cross-sectional area of 1.5mm², designed for convenient and reliable field wiring.
Contact Our Experts And Get A Free Consultation!
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.