Quality Three Phase Surge Arrester T2 T3 20KA 40KA SPD For Cold Northern Workshops factory
Quality Three Phase Surge Arrester T2 T3 20KA 40KA SPD For Cold Northern Workshops factory
Quality Three Phase Surge Arrester T2 T3 20KA 40KA SPD For Cold Northern Workshops factory
Quality Three Phase Surge Arrester T2 T3 20KA 40KA SPD For Cold Northern Workshops factory
>

Three Phase Surge Arrester T2 T3 20KA 40KA SPD For Cold Northern Workshops

Product Summary

Wide-temperature 3+NPE surge arrester engineered for sealed high-temp cabinets and cold northern workshops, rated up to 80℃ versus standard 70℃ SPD limits, with consistent residual voltage and surge capacity in unventilated power enclosures and hot production lines. Dedicated low-temperature thermal ...

Product Custom Attributes

Temp Operating Band:
-40℃ Cold Up To +80℃ Hot
Max N-E Residual Voltage:
Uniform ≤1.5kV
Thermal Safety:
Integrated Ultra-Low Temp Release
Mount Location:
Indoor DIN Rail Terminal Panels
Lightning Zones:
LPZ1, LPZ2 Secondary Areas
Highlight:

Three Phase Surge Arrester T2 T3

,

20KA 40KA SPD for workshops

,

Cold Northern SPD with warranty

Basic Properties

Place of Origin:
China
Brand Name:
LLH
Model Number:
LPM 80-385/3+NPE

Trading Properties

Minimum Order Quantity:
1 piece
Packaging Details:
Box
Delivery Time:
7-15 days
Payment Terms:
L/C,D/A,D/P,T/T,Western Union
Supply Ability:
5000-10000 pieces/mouth

Product Description

Wide-temperature 3+NPE surge arrester engineered for sealed high-temp cabinets and cold northern workshops, rated up to 80℃ versus standard 70℃ SPD limits, with consistent residual voltage and surge capacity in unventilated power enclosures and hot production lines. Dedicated low-temperature thermal release prevents unnecessary tripping at -40℃ extreme cold, while uniform N-E residual voltage ≤1.5kV pairs with GMR phase low-residual technology for full three-phase coverage. Plug-in modules simplify maintenance in hot/cold equipment rooms, 12mm standard wire strip supports standardized field wiring, IP20 indoor rating for surge suppression on automation lines, high-heat machinery rooms and cold factory control terminals.


Product features
●  Extended rated high-temperature limit reaching 80℃.
●  No false thermal tripping under -40℃ frigid ambient.
●  Stable residual voltage through hot-cold temperature cycles.
●  Integrated thermal release isolates faulty modules automatically.
●  Compatible with industrial cabinets with large temperature swings

●  Suitable for installation in LPZ 1 -2 and subsequent lightning protection zones , it is used as a fine lightning arrester for three-phase power supply systems .


Specification

Three Phase Surge Arrester T2 T3 20KA 40KA SPD For Cold Northern Workshops 0

Based on criteria

GB/T 18802.11-2020

SPD type

T2,T3

SPD model

SLV 20-385/3+NPE

SLV 20-320/3+NPE

Electrical parameters

Nominal operating voltage Un

220Vac(50Hz)

Maximum continuous operating voltage Uc

385Vac(50Hz)

320Vac(50Hz)

Nominal discharge current (8/20μs)In

20kA

20kA

Maximum discharge current (8/20μs)Imax

40kA

40kA

Voltage protection level In@Up

L-N:≤1 .3kV

N-E:≤1 .5kV

L-N:≤1 .0kV

N-E:≤1 .5kV

L 123-N(3kA&6kV) Uoc

≤600V

≤800V

Response time tA

L-N:≤25ns

N-E:≤100ns

Protected mode

L1,L2,L3-N,N-E

Mechanical parameters

Way to install

DIN 35mm guide rail

Screw torque

5 N*m

Strand length

12mm

Wiring cross-sectional area

2.5mm²-32mm²

Product size

90mmx72mmx68mm

Shell Material and Flame Retardant Rating

Mineral nylon PA6 ,V0

Warning system

Degradation indicator

Green window: OK; red window: Fail

Remote communication contact type

Normally closed , normally open switching contact

Remote communication contact switching capability

125Vac/1A,125Vdc/0 .2A

Work environment

Installation site

Indoor

Outer shell protection rating

IP20

Temperature range

-40℃…+80℃

Humidity range

Relative humidity ≤95% (max 40°C)


FAQ

Q1: Does 80℃ rating allow continuous 80℃ non-stop operation?

A: It is the maximum rated operating point; consistent performance is guaranteed with basic cabinet ventilation. 


Q2: Does the low-temperature release reduce normal surge diversion capacity?

 A: The mechanism only activates upon module overheating failure, remaining inactive during standard lightning and switching transients.


Q3:Are cooling fans mandatory for high-temperature cabinet installation?

 A:Not required for standard enclosures; auxiliary ventilation is recommended for fully sealed zero-airflow cabinets.

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.