lightning arrester box
"
Προστασία από κεραυνούς για όλο το σπίτι, Αντικεραυνική προστασία χαμηλής τάσης 220V 320V 20kA 40kA 80kA AC SPD
Description Suitable for installation in LPZ 1-2 and subsequent lightning protection zones, suitable for fine lightning protection in single-phase power supply systems. Features 1.Full mode protection 2. Large flow capacity and super low residual pressure 3.No leakage current, no afterflow Parameter Standard IEC 61643.11 SPD type T2,T3 Models SLV-40S SLV-80S Parameter Nominal operating voltage Un 220Vac(50Hz) Maximum continuous operating voltage Uc 320Vac(50Hz) Nominal
Προστατευτικό Υπέρτασης Gigabit PoE RJ45 10Gbps POE 5V 8V 48V 60V Προστατευτικό Κεραυνών Δικτύου Επικοινωνίας
Product Features ● Modular design, metal casing, strong anti-interference ability. ● DIN 35mm rail, easy for expansion. ● Unique anti-interference circuit design, born for 10G communication network. ● Parallel protection circuit design, single-stage/ high-energy/ low residual voltage. ● Cat-6A surge protectors installed in LPZ 2-3 and subsequent surge protection zones and applied to 10G/10G BASE-T 802.3 computer network information systems Product Specification Parameter
Αντικεραυνική Προστασία Δικτύου 4 Καλωδίων Σήματος Ελέγχου 10kV 5V 12V 24V 48V PLC Αναλογικού Βρόχου
LS-CH Series 4-Wire Control Signal Lightning Arrester is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it provides comprehensive protection for four communication signal lines simultaneously. Featuring a hot-swappable module design, the product allows for module
Πολυκαναλικός μετρητής κεραυνών 9999 ψηφίων 0.5kA-100kA ρεύμα 2 καναλιών με διεπαφή επικοινωνίας RS485
Description This system is designed for monitoring and intelligent management of surge protectors, including recorded lightning strike counts, strike duration, remote signaling data, status of pre-breakers, and operational status of lightning arresters.Features • Display lightning arrester discharge count and status of two switch signals online • Microprocessing and digital storage ensure accurate data recording, interference-free operation, and data retention during power
2 Wire Signal SPD Network Surge Arrester 5V 60V DC 5Vdc 10kV PLC αισθητήρας πλήρης λειτουργίας
LS-W2 Series Ultra-Thin 2-Wire Control Signal Lightning Arrester (Full-Mode) is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it provides full-mode fine protection for two signal lines.Featuring an ultra-thin design (7mm thickness), the product saves space in
SPD Intelligent Monitor 3 Way MODBUS RTU Lightning Surge Protection
Product Features● One channel NTC acquisition port: measure the surface temperature of SPD, with ultra/low temperature alarm function, threshold can be set, and independent alarm indicator can record 30 times (register reading) of alarm times and the date and time of alarm occurrence.● One lightning surge collection port: monitoring line surge current, triggering threshold of 500A, T1/T2/T3 compatible. The surge count is displayed locally for 0-9999 times, and the register
Συσκευή προστασίας από κεραυνό 2 Σύρμα σήματος SPD 5kA 10kV DIN Σιδηροδρομική τοποθέτηση
LS-CS Series 2-Wire Control Signal Lightning Arrester (Full-Mode) is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it provides full-mode fine protection for two signal lines.Featuring an integrated module structure, the product supports 35mm DIN Rail mounting with
Προστασία από Κεραυνούς T1 T2 SPD 3 Φάσεων Οικιακός Αντικεραυνικός Προστατευτής 220V 25kA 40kA 80kA
LPM 25B-385/4/LPM 50B-385/4 is a T1+T2 level power surge protector. It integrates primary (T1) and secondary (T2) protection, providing comprehensive shielding against direct and indirect lightning strikes. Product features • Integrated module design:Integrated module design enables hot-swappable replacement, accurate surge protection, and cost-effective maintenance. • Support Kevin Connection:Featuring an integrated module design, ensuring accurate current measurement and
Αντικεραυνική Προστασία Υπέρτασης 3 Φάσεων 220V 385V 40kA 80kA Προστασία από Υπέρταση Κεραυνού για Σπίτι
The LPM 80-385/4 is a Type T2 three-phase surge protective device (SPD) engineered to defend three-phase AC power distribution systems from lightning-induced surges and transient overvoltages. Built for installation in LPZ 0B+ and subsequent lightning protection zones, this unit delivers robust, reliable protection for both commercial and industrial infrastructure. Product features ● The module is designed to be pluggable and anti vibration. ● Built in ultra-low temperature