Signal Lightning Arrester 5V 6V DC 2 Wire Line Line Gigabit Ethernet Surge Protector
Product Summary
LS-CHL Series 2-Wire Control Signal Lightning Arrester (Line-Line Mode) is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and ...
Product Custom Attributes
Signal Lightning Arrester 5V
,Line Line Gigabit Ethernet Surge Protector
,Communication Equipment Signal Lightning Arrester
Basic Properties
Trading Properties
Product Description
LS-CHL Series 2-Wire Control Signal Lightning Arrester (Line-Line Mode) is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it provides line-line mode fine protection for two signal lines.
Featuring a plug-in module design, the product allows for easy replacement without interrupting signal transmission. The multi-level protection circuit ensures high flow rate and low residual voltage, specifically optimizing line-line surge protection. With a line-to-line bandwidth of 3MHz, it supports high-speed signal transmission without distortion.
| Product Features |
|
●Large flow rate, low residual pressure.
|
|
●Line-GND mode fine protection.
|
|
●The module can be replaced by plug-in without interrupting the signal transmission.
|
|
●Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it is a lightning arrester for communication equipment such as communication dedicated lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops.
|
Product Specification

| Standards | IEC 61643.21 | |||
| Models | LS-CH5L | LS-CH12L | LS-CH24L | LS-CH48L |
| Parameter | ||||
| Nominal operating voltage Un | 5Vdc | 12Vdc | 24Vdc | 48Vdc |
| Maximum continuous operating voltage Uc | 6Vdc | 18Vdc | 32Vdc | 60Vdc |
| X-X,X-C Shock rating C2 | 10kV/5kA | |||
| X-X,X-C Shock rating B2 | 4kV(10/700μs) | |||
| X-X,X-C Shock rating D1 | 2.5kA(10/350μs) | |||
| X-X Up@C2 | ≤15V | ≤30V | ≤60V | ≤95V |
| X-C Up@C2 | ≤500V | |||
| X-X Up@B2 | ≤10V | ≤25V | ≤45V | ≤60V |
| X-C Up@B2 | ≤300V | |||
| Response time tA | ≤1ns | |||
| Load current IR | 500mA | |||
| Line to line bandwidth fG | 3MHz | |||
| Protective Line | X1-X2,X1-C,X2-C | |||
|
Installation method
|
DIN Rail 35mm
|
|
Screw torque
|
1N*m
|
|
Strip length
|
10mm
|
|
Wiring cross-sectional area
|
0.5mm2-2.5mm2
|
|
Product size
|
90mmx65mmx13mm
|
|
Shell material and flame retardant grade
|
PC+ABS,UL 94 V-0
|
|
Installation location
|
Indoor
|
|
Shell protection rating
|
IP20
|
|
Temperature range
|
-40℃…+80℃
|
|
Humidity range
|
Relative humidity≤95%
|
Notices
1.This product adopts line-line mode protection, suitable for scenarios where line-line surges are the main threat.
2.Select the model based on the signal line's nominal operating voltage (5Vdc/12Vdc/24Vdc/48Vdc).
3.Use wiring with cross-sectional area 0.5mm²-2.5mm² and tighten screws to 1N·m torque.
4.Ensure reliable grounding with ground resistance ≤4Ω to guarantee surge diversion.
5.Avoid installing in environments with strong electromagnetic interference to prevent signal distortion.
6.Regularly inspect the module for loose connections or physical damage; replace if faulty.
FAQ
Q1: What is the difference between line-line mode and line-ground mode?
A1: Line-line mode focuses on protecting against surges between two signal lines, while line-ground mode protects against surges between signal lines and ground.
Q2: Can this product be used for differential signal lines?
A2: Yes, line-line mode protection is ideal for differential signal lines, providing targeted surge shielding.
Q3: What is the load current capacity of the product?
A3: The maximum load current is 500mA, suitable for most industrial control signal lines.
Q4: Does the product require external power supply?
A4: No, it is passive and does not require external power supply, drawing minimal power from the signal line.
Q5: What is the voltage protection level for line-ground surges?
A5: The line-ground voltage protection level is ≤300V, providing basic line-ground surge protection while focusing on line-line protection.
Contact Our Experts And Get A Free Consultation!
Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.