Quality Lightning Protection Device 2 Wire Signal SPD 5kA 10kV DIN Rail Mounting factory
<
Quality Lightning Protection Device 2 Wire Signal SPD 5kA 10kV DIN Rail Mounting factory
Quality Lightning Protection Device 2 Wire Signal SPD 5kA 10kV DIN Rail Mounting factory
Quality Lightning Protection Device 2 Wire Signal SPD 5kA 10kV DIN Rail Mounting factory
Quality Lightning Protection Device 2 Wire Signal SPD 5kA 10kV DIN Rail Mounting factory
Quality Lightning Protection Device 2 Wire Signal SPD 5kA 10kV DIN Rail Mounting factory
Quality Lightning Protection Device 2 Wire Signal SPD 5kA 10kV DIN Rail Mounting factory
>

Lightning Protection Device 2 Wire Signal SPD 5kA 10kV DIN Rail Mounting

Product Summary

LS-CS Series 2-Wire Control Signal Lightning Arrester (Full-Mode) is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and ...

Product Custom Attributes

Standards:
IEC 61643.21
SPD Type:
Control Signal Surge Protector
Nominal Operating Voltage (Un):
5Vdc / 12Vdc / 24Vdc / 48Vdc
Shock Rating (X-X,X-C C2):
10kV/5kA
Shock Rating (X-X,X-C B2):
4kV(10/700μs)
Shock Rating (X-X,X-C D1):
2.5kA(10/350μs)
Voltage Protection Level (X-X @C2):
≤15V / ≤30V / ≤60V / ≤95V
Response Time (tA):
≤1ns
Highlight:

Lightning Protection Device 10kV

,

DIN Rail Mounting Signal SPD

,

Signal SPD 5kA

Basic Properties

Place of Origin:
Guangdong Province.China
Brand Name:
LLH
Model Number:
LS-CS5
Document:

Trading Properties

Minimum Order Quantity:
1 piece
Price:
US $8/ Piece
Packaging Details:
box
Delivery Time:
7-15 days
Payment Terms:
L/C,D/A,D/P,T/T,Western Union
Supply Ability:
5000-10000 pieces/mouth

Product Description

LS-CS Series 2-Wire Control Signal Lightning Arrester (Full-Mode) is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it provides full-mode fine protection for two signal lines.

Featuring an integrated module structure, the product supports 35mm DIN Rail mounting with through flow. The multi-level protection circuit ensures high flow rate and low residual voltage, covering both line-line and line-ground surge paths. With a line-to-line bandwidth of 3MHz, it supports high-speed signal transmission without distortion.

 

Product Features
● Integrated modular structure.
● Support the installation of 35mm rail through flow.
● Low residual pressure. 
● Full-mode fine protection.
● Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it is a lightning arrester for communication equipment such as communication dedicated lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops.

 

Product Specification

 

Lightning Protection Device 2 Wire Signal SPD 5kA 10kV DIN Rail Mounting 0

StandardsIEC 61643.21
ModelsLS-CS5LS-CS12LS-CS24LS-CS48
Parameter
Nominal operating voltage Un5Vdc12Vdc24Vdc48Vdc
Maximum continuous operating voltage Uc6Vdc18Vdc32Vdc60Vdc
X-X,X-C Shock rating C210kV/5kA
X-X,X-C Shock rating B24kV(10/700μs)
X-X,X-C Shock rating D12.5kA(10/350μs)
X-X Up@C2≤15V≤30V≤60V≤95V
X-C Up@C2≤15V≤30V≤60V≤95V
X-X Up@B2≤10V≤25V≤45V≤60V
X-C Up@B2≤10V≤25V≤45V≤60V
Response time tA≤1ns
Load current IR500mA
Line to line bandwidth fG3MHz
Protective LineX1-X2,X1-C,X2-C

 

Mechanical parameters
 
Installation method
DIN Rail 35mm
Screw torque
1N*m
Strip length
10mm
Wiring cross-sectional area
0.5mm²-2.5mm²
Product size
90mmx65mmx18mm
Shell material and flame retardant grade
PC+ABS,UL 94 V-0
Installation location
Indoor
Shell protection rating
IP20
Temperature range
-40℃…+80℃
Humidity range
Relative humidity≤95%

 

Notices

1.This product adopts full-mode protection, covering both line-line and line-ground surge paths.

2.Select the model based on the signal line's nominal operating voltage (5Vdc/12Vdc/24Vdc/48Vdc).

3.Use wiring with cross-sectional area 0.5mm²-2.5mm² and tighten screws to 1N·m torque.

4.Ensure reliable grounding with ground resistance 4Ω to guarantee surge diversion.

5.Avoid installing in environments with strong electromagnetic interference to prevent signal distortion.

6.Regularly inspect the module for loose connections or physical damage; replace if faulty.
 

FAQ

Q1: What is the advantage of the integrated module structure?

A1: The integrated module structure enhances stability and reduces mutual interference, ensuring reliable performance in complex industrial environments.

 

Q2: Can this product be used for both DC and AC signal lines?

A2: It is specifically designed for DC signal lines (5Vdc/12Vdc/24Vdc/48Vdc). For AC signals, choose dedicated AC signal SPD models.

 

Q3: What is the load current capacity of the product?

A3: The maximum load current is 500mA, suitable for most industrial control signal lines.

 

Q4: Does the product require external power supply?

A4: No, it is passive and does not require external power supply, drawing minimal power from the signal line.

 

Q5: What is the service life of the product?

A5: Under normal operating conditions, the service life is 5-8 years. It may vary based on surge frequency and environmental factors.

Attachments