Whole House Signal Surge Protective Device 2 Wire Line Line 5Vdc 10kV PLC Control Industrial
Product Summary
LS-CS5L Series 2-Wire Control Signal Lightning Arrester (Line-Line Mode) is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and ...
Product Custom Attributes
Whole House Surge Protection Device 5Vdc
,Signal Surge Protective Device 10kV
,Industrial Signal Surge Protective Device
Basic Properties
Trading Properties
Product Description
LS-CS5L Series 2-Wire Control Signal Lightning Arrester (Line-Line Mode) is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it provides line-line mode fine protection for two signal lines.
Featuring an integrated module structure, the product supports 35mm DIN Rail mounting with through flow. The multi-level protection circuit ensures high flow rate and low residual voltage, specifically optimizing line-line surge protection. With a line-to-line bandwidth of 3MHz, it supports high-speed signal transmission without distortion.
| Product Features |
|
● Integrated module structure.
|
|
● Support for 35mm rail mounting.
|
|
● Large flow rate, low residual pressure.
|
|
● Line-Line mode fine protection.
|
|
● Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it is a lightning arrester for communication equipment such as communication dedicated lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops.
|

| Standards | IEC 61643.21 | |||
| Models | LS-CS5L | LS-CS12L | LS-CS24L | LS-CS48L |
| Parameter | ||||
| Nominal operating voltage Un | 5Vdc | 12Vdc | 24Vdc | 48Vdc |
| Maximum continuous operating voltage Uc | 6Vdc | 18Vdc | 32Vdc | 60Vdc |
| X-X,X-C Shock rating C2 | 10kV/5kA | |||
| X-X,X-C Shock rating B2 | 4kV(10/700μs) | |||
| X-X,X-C Shock rating D1 | 2.5kA(10/350μs) | |||
| X-X Up@C2 | ≤15V | ≤30V | ≤60V | ≤95V |
| X-C Up@C2 | ≤500V | |||
| X-X Up@B2 | ≤10V | ≤25V | ≤45V | ≤60V |
| X-C Up@B2 | 300V | |||
| Response time tA | ≤1ns | |||
| Load current IR | 500mA | |||
| Line to line bandwidth fG | 3MHz | |||
| Protective Line | X1-X2,X1-C,X2-C | |||
Mechanical parameters
| Installation method | DIN Rail 35mm |
| Screw torque | 1N*m |
| Strip length | 10mm |
| Wiring cross-sectional area | 0.5mm²-2.5mm² |
| Product size | 90mmx65mmx18mm |
| Shell material and flame retardant grade | PC+ABS,UL 94 V-0 |
| Installation location | Indoor |
| Shell protection rating | IP20 |
| Temperature range | -40℃…+80℃ |
| Humidity range | Relative humidity≤95% |
Notices
1.This product adopts line-line mode protection, suitable for scenarios where line-line surges are the main threat.
2.Select the model based on the signal line's nominal operating voltage (5Vdc/12Vdc/24Vdc/48Vdc).
3.Use wiring with cross-sectional area 0.5mm²-2.5mm² and tighten screws to 1N·m torque.
4.Ensure reliable grounding with ground resistance ≤4Ω to guarantee surge diversion.
5.Avoid installing in environments with strong electromagnetic interference to prevent signal distortion.
6.Regularly inspect the module for loose connections or physical damage; replace if faulty.
FAQ
Q1: What is the difference between full-mode and line-line mode protection?
A1: Full-mode protection covers line-line and line-ground paths, while line-line mode only protects line-line paths. This product optimizes line-line protection.
Q2: Can this product be used for differential signal lines?
A2: Yes, line-line mode protection is ideal for differential signal lines, providing targeted surge shielding.
Q3: What is the load current capacity of the product?
A3: The maximum load current is 500mA, suitable for most industrial control signal lines.
Q4: Does the product require external power supply?
A4: No, it is passive and does not require external power supply, drawing minimal power from the signal line.
Q5: What is the voltage protection level for line-ground surges?
A5: The line-ground voltage protection level is ≤300V, providing basic line-ground surge protection while focusing on line-line protection.