Quality 2 Wire Signal SPD Network Surge Arrester 5V 60V DC 5Vdc 10kV PLC Sensor Full Mode factory
<
Quality 2 Wire Signal SPD Network Surge Arrester 5V 60V DC 5Vdc 10kV PLC Sensor Full Mode factory
Quality 2 Wire Signal SPD Network Surge Arrester 5V 60V DC 5Vdc 10kV PLC Sensor Full Mode factory
>

2 Wire Signal SPD Network Surge Arrester 5V 60V DC 5Vdc 10kV PLC Sensor Full Mode

Product Summary

LS-W2 Series Ultra-Thin 2-Wire Control Signal Lightning Arrester (Full-Mode) is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 ...

Product Custom Attributes

Standards:
IEC 61643.21
Nominal Operating Voltage (Un):
5Vdc / 12Vdc / 24Vdc / 48Vdc
Maximum Continuous Operating Voltage (Uc):
6Vdc / 18Vdc / 32Vdc / 60Vdc
Shock Rating (X-X,X-C C2):
10kV/5kA
Shock Rating (X-X,X-C B2):
4kV(10/700μs)
Shock Rating (X-X,X-C D1):
2.5kA(10/350μs)
Voltage Protection Level (X-X @C2):
≤15V / ≤30V / ≤60V / ≤95V
Response Time (tA):
≤1ns
Highlight:

2 Wire Signal SPD

,

Network Surge Arrester 5V

,

PLC Sensor Signal SPD

Basic Properties

Place of Origin:
Guangdong Province.China
Brand Name:
LLH
Model Number:
LS-5W2
Document:

Trading Properties

Minimum Order Quantity:
1 piece
Price:
US $10/ Piece
Packaging Details:
box
Delivery Time:
7-15 days
Payment Terms:
L/C,D/A,D/P,T/T,Western Union
Supply Ability:
5000-10000 pieces/mouth

Product Description

LS-W2 Series Ultra-Thin 2-Wire Control Signal Lightning Arrester (Full-Mode) is designed for communication equipment such as dedicated communication lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops. Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it provides full-mode fine protection for two signal lines.

Featuring an ultra-thin design (7mm thickness), the product saves space in control cabinets, making it ideal for space-constrained environments. The module comes with guide rail ground contact, enhancing grounding reliability. The multi-level protection circuit ensures high flow rate and low residual voltage, covering both line-line and line-ground surge paths.

 

Product Features
● Ultra-thin design saves space.
● The module comes with guide rail ground contact.
● High flow rate, low residual pressure.
● Full-mode precision protection.
● Suitable for installation in LPZ 2-3 and subsequent lightning protection zones, it is a lightning arrester for communication equipment such as communication dedicated lines, telemetry signals, measurement and control signals, PLC analog control systems, and 4-20mA current loops.

 

Product Specification

 

2 Wire Signal SPD Network Surge Arrester 5V 60V DC 5Vdc 10kV PLC Sensor Full Mode 0

 

StandardsIEC 61643.21
ModelsLS-5W2LS-12W2LS-24W2LS-48W2
Parameter
Nominal operating voltage Un5Vdc12Vdc24Vdc48Vdc
Maximum continuous operating voltage Uc6Vdc18Vdc32Vdc60Vdc
X-X,X-C Shock rating C2
10kV/5kA
X-X,X-C Shock rating B24kV(10/700μs)
X-X,X-C Shock rating D12.5kA(10/350μs)
X-X Up@C2≤15V≤30V≤60V≤95V
X-C Up@C2≤15V≤30V≤60V≤95V
X-X Up@B2≤10V≤25V≤45V≤60V
X-C Up@B2≤10V≤25V≤45V≤60V
Response time tA≤1ns
Load current IR500mA
Line to line bandwidth fG3MHz
Protective LineX1-X2,X1-C,X2-C

 

Mechanical parameters
 
Installation method
DIN Rail 35mm
Screw torque
1N*m
Strip length
10mm
Wiring cross-sectional area
0.5mm²-2.5mm²
Product size
90mmx65mmx7mm
Shell material and flame retardant grade
ABS,UL 94 V-0
Installation location
Indoor
Shell protection rating
IP20
Temperature range
-40℃…+80℃
Humidity range
Relative humidity≤95%

 

Notices

1.The ultra-thin design (7mm) saves space, but avoid installing in areas with strong mechanical impact.

2.Select the model based on the signal line's nominal operating voltage (5Vdc/12Vdc/24Vdc/48Vdc).

3.The module comes with guide rail ground contact; ensure the DIN Rail is properly grounded.

4.Use wiring with cross-sectional area 0.5mm²-2.5mm² and tighten screws to 1N·m torque.

5.Avoid installing in environments with strong electromagnetic interference to prevent signal distortion.

6.Regularly inspect the module for loose connections or physical damage; replace if faulty.

 

FAQ

Q1: What is the thickness of the product?

A1: The product thickness is only 7mm, featuring an ultra-thin design to save space in control cabinets.

 

Q2: What is the function of the guide rail ground contact?

A2: It enhances grounding reliability by utilizing the DIN Rail as a ground path, simplifying installation.

 

Q3: What is the load current capacity of the product?

A3: The maximum load current is 500mA, suitable for most industrial control signal lines.

 

Q4: Does the product require external power supply?

A4: No, it is passive and does not require external power supply, drawing minimal power from the signal line.

 

Q5: Can it be used for both DC and AC signal lines?

A5: It is specifically designed for DC signal lines (5Vdc/12Vdc/24Vdc/48Vdc). For AC signals, choose dedicated AC signal SPD models.

Attachments

Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.